Uncapped Photovoltaic Connectors - A Combined Field and Chamber Study to Verify and Elucidate Degradation

  • National Laboratory of the Rockies

Research output: Contribution to conference › Paper

Abstract

"Uncapped connectors" are left open to the environment prior to PV system installation, where corrosion and contamination may occur between mechanical mounting and their subsequent electrical connection. We conducted a study to verify the damage mode and further inform the industry on the presently widespread practice of uncapped connectors. Replicate connectors were deployed in the summer of 2023 in: hot-dry Barstow, CA; subtropical Gaithersburg, MD; and ocean side Prince Edward Island, CAN. Connectors were returned and then additionally aged using combined-accelerated stress testing (C-AST). Characterizations included: visual and thermographic imaging, resistance-current sweep, HiPot wet leakage insulation, and scanning electron microscopy (morphology and composition, surface and depth-profiling). Deconstructed samples (from the field and after C-AST) showed overt differences between outdoor locations, including: morphology (surface cracking), contamination (minerals, salts, and organic matter), and chemical integrity (surface scale and corrosion). While the performance of field-aged, uncapped connectors was not immediately distinguished from plugged or unaged connectors, all uncapped specimen assemblies ultimately failed C-AST. The humid locations failed 3 - 5 test sequences earlier than the hot-dry location, emphasizing the adverse impact of water and salt. Having confirmed the damage mode of uncapped connectors from simple, prolonged exposure to the outdoor environment, we recommend to always use the manufacturer's protective end caps, from the time of module manufacture until PV is fully installed in the field.
Original languageAmerican English
Number of pages8
DOIs
StatePublished - 2025
EventIEEE Holm Conference on Electrical Contacts - San Antonio, TX
Duration: 15 Oct 2025 → 22 Oct 2025

Conference

ConferenceIEEE Holm Conference on Electrical Contacts
CitySan Antonio, TX
Period15/10/25 → 22/10/25

NLR Publication Number

  • NLR/CP-5K00-99589

Keywords

  • cable connectors
  • combined accelerated stress testing (C-AST)
  • contamination
  • corrosion
  • durability
  • EDS
  • International PV Quality Assurance Task Force (PVQAT)
  • reliability
  • SEM
  • XCT

Fingerprint

Dive into the research topics of 'Uncapped Photovoltaic Connectors - A Combined Field and Chamber Study to Verify and Elucidate Degradation'. Together they form a unique fingerprint.

Cite this