Abstract
This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detailmaking use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).
| Original language | American English |
|---|---|
| Publisher | National Laboratory of the Rockies (NLR) |
| Number of pages | 83 |
| State | Published - 2012 |
Bibliographical note
Work performed by Building Science Corporation (BSC), Somerville, MassachusettsNLR Publication Number
- NREL/SR-5500-54208
Other Report Number
- DOE/GO-102012-3637
Keywords
- basement
- BSC
- foundation
- insulation
- water management