Abstract
In this work, we present a methodology to separate effects of perovskite device metastability from irreversible degradation, using stress/rest cycling under constant current bias while collecting a series of electroluminescence images and continuously monitoring voltage. We develop a simulation model and procedures for image processing to better understand the effects of ion parameters on the transient nature of voltage and evolving electroluminescence images.
| Original language | American English |
|---|---|
| Number of pages | 8 |
| State | Published - 2021 |
| Event | 48th IEEE Photovoltaic Specialists Conference (PVSC 48) - Duration: 20 Jun 2020 → 25 Jun 2020 |
Conference
| Conference | 48th IEEE Photovoltaic Specialists Conference (PVSC 48) |
|---|---|
| Period | 20/06/20 → 25/06/20 |
Bibliographical note
See NREL/CP-5K00-81134 for paper as published in proceedingsNLR Publication Number
- NREL/CP-5K00-80422
Keywords
- luminescence imaging
- perovskite
- reliability
- transient voltage
Fingerprint
Dive into the research topics of 'Linking Transient Voltage to Spatially-Resolved Luminescence Imaging to Understand Reliability of Perovskite Photovoltaics: Preprint'. Together they form a unique fingerprint.Cite this