Abstract
A set of validation test cases is presented to compare the results of midlevel detailed ground-coupled heat transfer models typically used with whole-building energy simulation software.
| Original language | American English |
|---|---|
| Number of pages | 11 |
| State | Published - 2009 |
| Event | Building Simulation 2009 Conference - Glasgow, Scotland Duration: 27 Jul 2009 → 30 Jul 2009 |
Conference
| Conference | Building Simulation 2009 Conference |
|---|---|
| City | Glasgow, Scotland |
| Period | 27/07/09 → 30/07/09 |
NLR Publication Number
- NREL/CP-550-45742
Keywords
- bestest-ex self-testing procedure
- building energy simulation test for existing homes (BESTEST-EX)
- ground-coupled heat transfer
- slab-on-grade
Fingerprint
Dive into the research topics of 'IEA BESTEST In-Depth Diagnostic Cases for Ground Coupled Heat Transfer Related to Slab-on-Grade Construction: Preprint'. Together they form a unique fingerprint.Cite this