Abstract
Two identical laboratory homes designed to model existing Florida building stock were sealed and tested to 2.5 ACH50. Then, one was made leaky with 70% leakage through the attic and 30% through windows, to a tested value of 9 ACH50. Reduced energy use was measured in the tighter home (2.5 ACH50) in the range of 15% to 16.5% relative to the leaky (9 ACH50) home. Internal moisture loads resulted inhigher dew points inside the tight home than the leaky home. Window condensation and mold growth occurred inside the tight home. Even cutting internal moisture gains in half to 6.05 lbs/day, the dew point of the tight home was more than 15 degrees F higher than the outside dry bulb temperature. The homes have single pane glass representative of older Central Florida homes.
| Original language | American English |
|---|---|
| Publisher | National Laboratory of the Rockies (NLR) |
| Number of pages | 33 |
| State | Published - 2013 |
Bibliographical note
Work performed by BA-PIRC/Florida Solar Energy Center, Cocoa, FloridaNLR Publication Number
- NREL/SR-5500-60118
Other Report Number
- DOE/GO-102013-4041
Keywords
- BA-PIRC
- building air leakage
- Building America
- infiltration
- internal moisture gains
- residential
- residential buildings
Fingerprint
Dive into the research topics of 'Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Heating Season Energy and Moisture Levels'. Together they form a unique fingerprint.Cite this