Abstract
Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.
| Original language | American English |
|---|---|
| Pages (from-to) | 1532-1539 |
| Number of pages | 8 |
| Journal | IEEE Open Journal of Power Electronics |
| Volume | 7 |
| DOIs | |
| State | Published - 2026 |
NLR Publication Number
- NLR/JA-5K00-100558
Keywords
- FMEA
- inverter reliability
- photovoltaic
- PV inverter
- risk priority number
Fingerprint