Abstract
To determine potential for reduction in the cost of saved energy (COSE) for cold-climate solar domestic hot water (SDHW) systems, COSE was computed for three types of cold climate water heating systems. For each system, a series of cost-saving measures was considered: 1) balance of systems (BOS): tank, heat exchanger, and piping-valving measures; and 2) four alternative lower-cost collectors.Given all beneficial BOS measures in place, >50% reduction of COSE was achievable only with selective polymer collectors at half today's selective collector cost. In all three system types, today's metal-glass selective collector achieved the same COSE as the hypothesized non-selective polymer collector.
| Original language | American English |
|---|---|
| Number of pages | 5 |
| State | Published - 2005 |
| Event | 2004 DOE Solar Energy Technologies Program Review Meeting - Denver, Colorado Duration: 25 Oct 2004 → 28 Oct 2004 |
Conference
| Conference | 2004 DOE Solar Energy Technologies Program Review Meeting |
|---|---|
| City | Denver, Colorado |
| Period | 25/10/04 → 28/10/04 |
Bibliographical note
Presented at the 2004 DOE Solar Energy Technologies Program Review Meeting, 25-28 October 2004, Denver, Colorado. Also included in the proceedings available on CD-ROM (DOE/GO-102005-2067; NREL/CD-520-37140)NLR Publication Number
- NREL/CP-550-37105
Keywords
- balance of systems (BOS)
- cold climate
- cost of saved energy (COSE)
- heating systems
- metal glass selective collector
- PV
- solar domestic hot water (SDHW)
Fingerprint
Dive into the research topics of 'Cold-Climate Solar Domestic Hot Water Systems: Cost/Benefit Analysis and Opportunities for Improvement'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver