Abstract
Energy efficiency (EE) retrofitting often overlooks indoor overheating risks (HR) in non-air-conditioned homes during summer. This study applies NSGA-II optimization to Baltimore rowhouses to balance EE and HR. Relative to the International Energy Conservation Code (IECC) 2021 baseline, the lowest-risk solution reduced HR by 13.5-16.8 % without increasing heating energy use, featuring higher wall and roof R-values, lower window U-factor and SHGC, and higher infiltration rate. Under future (2080-2099) weather scenario, optimal parameters followed a similar trend, but experienced a 140-421 % rise in overheating hours, alongside a 3-6 % decrease in heating demand relative to current conditions. In conclusion, modest adjustments to IECC 2021 could reduce summertime overheating risks without compromising energy performance.
| Original language | American English |
|---|---|
| Pages | 444-453 |
| Number of pages | 10 |
| DOIs | |
| State | Published - 2026 |
| Event | Twelfth National Conference of IBPSA-USA - Minneapolis, MN Duration: 20 May 2026 → 22 May 2026 |
Conference
| Conference | Twelfth National Conference of IBPSA-USA |
|---|---|
| City | Minneapolis, MN |
| Period | 20/05/26 → 22/05/26 |
NLR Publication Number
- NLR/CP-5500-98005
Keywords
- energy efficiency
- envelope optimization
- overheating risks
- rowhouses
- thermal resilience
Fingerprint
Dive into the research topics of 'Balancing Energy Efficiency and Overheating Risks: Optimal Retrofit Pathways for Baltimore Rowhouses'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver