Skip to main navigation Skip to search Skip to main content

Anion-Exchange Membrane Water Electrolysis: Insights from Round-Robin Testing: Article No. 1794912

  • Melissa Kreider
  • , B. Milenia Rojas Mendoza
  • , Luke Brusse
  • , Duha Syar
  • , Minkyoung Kwak
  • , Patrick Yang
  • , Hung-Ming Chang
  • , Ryan Hannagan
  • , Isabela Rios Amador
  • , Anthony Ekennia
  • , Nicholas Oliveira
  • , Adam Nielander
  • , Shannon Boettcher
  • , Iryna Zenyuk
  • , Thomas Jaramillo
  • , Shaun Alia
  • , Balsubramanian Lakshmanan
  • SLAC National Accelerator Laboratory
  • Stanford University
  • Versogen
  • University of California at Berkeley
  • University of California at Irvine
  • Nel

Research output: Contribution to journal › Article › peer-review

2 Scopus Citations

Abstract

As research and industrial interest in anion-exchange membrane water electrolysis (AEMWE) grows, there is an increasing need for reliable baselines and cross-lab validation of results. The wide variety of material sets and operating conditions under consideration for AEMWE has thus far limited efforts for standardization. In this study, round-robin testing was conducted in deionized water and KOH-based supporting electrolyte by 5 institutions from academia, national laboratories, and industry to provide baseline performance data and identify sources of cross-lab variability. Baseline membrane electrode assemblies were fabricated with commercial catalysts, membranes, and transport layers using standard techniques and tested using reagent-grade electrolytes, aiming for accessibility rather than state-of-the-art performance. From all tests, the average voltage at 1 A/cm2 was 2.72 +- 0.17 V and 1.87 +- 0.03 V in deionized water and 0.1 M KOH, respectively. The maximum in-house and cross-lab variations at this current density were 118 mV and 476 mV in water and 60 and 88 mV in 0.1 M KOH. The KOH purity, station contamination, and temperature control were identified as possible factors affecting performance between labs, with in-house specific variation attributed to sample-to-sample differences in fabrication, cell assembly, and station contamination. This work provides a commercial baseline for the field and highlights the need for improved standardization and reproducibility in AEMWE research.
Original languageAmerican English
Number of pages14
JournalFrontiers in Energy Research
Volume14
DOIs
StatePublished - 2026

NLR Publication Number

  • NLR/JA-5900-98404

Keywords

  • anion exchange membrane water electrolysis
  • benchmarking
  • hydrogen
  • round robin
  • water electrolysis

Fingerprint

Dive into the research topics of 'Anion-Exchange Membrane Water Electrolysis: Insights from Round-Robin Testing: Article No. 1794912'. Together they form a unique fingerprint.

Cite this